Toshiba 1600XP/XPi
Model 1600XP/XPi
Energy Efficiency + High Performance = Continuous Power
These double-conversion online UPS systems provide clean, conditioned power to ensure the safe and reliable operation of critical office equipment, IT systems, and sensitive electronics.
Battery Backup Time & Runtime Performance
Delivers reliable battery backup power with approximately 5–7 minutes of runtime at full load, depending on the specific kVA rating. Designed to protect critical equipment during power outages, runtime performance is based on operation at the rated power factor and can vary depending on battery condition, connected load type, ambient temperature, and overall system configuration. This dependable UPS battery discharge process ensures short-term power continuity, allowing for safe equipment operation or an orderly shutdown when utility power is lost.
Stabilizing Electrical Power
Supplies clean, conditioned power to connected loads while continuously maintaining its internal batteries in a fully charged state. Designed to safeguard critical IT and electrical equipment, the UPS protects against common commercial power disturbances such as power sags, surges, electrical noise, signal interference, and voltage spikes. This advanced power conditioning and protection prevents utility power issues from reaching sensitive devices, reducing the risk of equipment malfunction, data loss, and hardware or software damage.

Static Bypass Operation for Continuous UPS Power Protection
The UPS static bypass function automatically transfers power from the main inverter to the bypass circuit if the system detects a severe overload or internal fault. This automatic bypass operation occurs in phase and within less than one-quarter cycle of the input waveform, ensuring continuous power delivery with no noticeable interruption to most connected loads. By maintaining power flow during abnormal operating conditions, the static bypass system helps protect critical equipment and supports uninterrupted operation in demanding environments.
Battery Maintenance and Replacement
The Toshiba XP/XPi series uses sealed, valve-regulated lead-acid (VRLA) batteries that are maintenance-free in terms of watering or electrolyte service. While no routine servicing is required, regular inspection and testing are recommended to verify battery health and runtime performance.
Toshiba 1600XP/XPi 3.6kVA-22kVA Runtimes
| UPS Size | Runtime (full Load) |
| 3.6kVA 6.0kVA 8.0kVA 10kVA 14kVA 18kVA 22kVA | ~7-8mins ~7min ~7min ~5min ~7min ~5min ~3min |
Refer to your Toshiba 1600XP/XPi Manual for more battery details.
Not sure which Toshiba UPS fits your needs? Talk to QPS and get a customized quote.
Technical Specs
- Power Rating: 3.6-22kVA
- Power Factor: 0.85 output power factor
- Voltage: 208/240 Input; 240/208/120 Output
- Topology: True double-conversion online UPS
Features
- Output Isolation Transformer
- Angled terminal blocks for easy installation
- User friendly touch-screen display
- Generator compatible
Documentation
Options
- External Battery options
- Software & Connectivity options