Toshiba G9400

Model G9400


Continuous + Clean Power Delivery= High Reliability & Operational Efficiency

Three phase UPS system that features the latest generation of advanced Carrier Stored Trench Bi-Polar Transistor (CSTBT) IGBT technology, the “engine” of the UPS. The G9400 boasts an industry leading 97% true online efficiency at various loads. An ideal unit for hyper-scale data centers and other similar applications. The G9400’s unit design allows for N+1 Redundancy in various frame sizes, and boast an industry leading, compact footprint.

Industry-Leading Efficiency

The G9400 uses advanced 7th-gen CSTBT IGBT technology, delivering up to 97% online double-conversion efficiency — even at low load levels — which reduces electrical losses and cooling costs compared to less efficient UPS units

Flexible Battery and Generator Support

Works with a variety of battery types (VRLA, Nickel-Cadmium, and Toshiba SCiB Lithium-Titanate Oxide) for different runtime or lifecycle requirements. Also, generator-friendly design simplifies integration with onsite standby power.

Black industrial equipment with multiple sections and ventilation grilles, featuring a control panel on one side.

Designed for Easy Service and Lower Lifecycle Cost

Front-access design makes installation and maintenance easier.Plus it includes the Toshiba RemotEye®4 network card (SNMP/Modbus TCP) enables remote status, event logging, and alerts — letting IT teams watch and respond to issues without being on site.

The comparison chart above is designed to help engineers, facility managers, and IT decision-makers quickly evaluate the Toshiba G9400 Series UPS across both 400 V and 480 V platforms. By clearly outlining capacity ranges, voltage options, efficiency, redundancy features, monitoring capabilities, and battery compatibility, this chart makes it easy to identify the right UPS configuration for large-scale data centers, industrial facilities, and mission-critical infrastructure

Toshiba G9400 Comparison- 480V

Feature 1200kVA1600kVA2000kVA
Output Voltage480V, 3-Phase480V, 3-Phase480V, 3-Phase
UPS TopologyDouble-Conversion OnlineDouble-Conversion OnlineDouble-Conversion Online
Power ElectronicsIGBT Rectifier & InverterIGBT Rectifier & InverterIGBT Rectifier & Inverter
ScalabilityParallel-readyParallel-readyParallel-ready
Redundancy OptionsN+1 / N+XN+1 / N+XN+1 / N+X
Input Power Factor~0.99~0.99~0.99
Input Harmonic Distortion≤ 3% THDi≤ 3% THDi≤ 3% THDi
EfficiencyHigh efficiency at partial & full loadHigh efficiency at partial & full loadHigh efficiency at partial & full load
Maintenance AccessFront-accessFront-accessFront-access
MonitoringLCD + Network OptionsLCD + Network OptionsLCD + Network Options

Not sure which Toshiba UPS fits your needs? Talk to QPS and get a customized quote.

Request Pricing & Availability →

This field is for validation purposes and should be left unchanged.
Name(Required)
Email(Required)
Tell us what you need your UPS to protect, and we’ll help you find the right solution.

Technical Specs

  • Power Rating: 80, 100, 160, 225, 300, 500, & 750kVA
  • Output Power Factor: .9 up to 225kVA, 1.0 (Unity) 300-750kVA
  • Voltage: 480
  • Topology: True On-Line Double Conversion UPS

Features

  • IGBT Technology
  • Parallel up to eight units
  • Smallest footprint & highest power density in industry
  • SNMP/Web based monitoring

Options

  • Batteries & Flywheels
  • Tie Cabinet
  • Maintenance Bypass Cabinets
  • Power Distribution Units
  • Monitoring Options