24 Hour Emergency Power Services • Call 608-661-9910

DataSafe HX Top Terminated Batteries

The DataSafe® HX Top Terminated Batteries from EnerSys are a range of Valve Regulated Lead Acid (VRLA) batteries built for Information Technology and Uninterruptible Power Supply (UPS) applications.

Locked

The DataSafe® HX Top Terminated Batteries from EnerSys are a range of Valve Regulated Lead Acid (VRLA) batteries built for Information Technology and Uninterruptible Power Supply (UPS) applications. Available in 6 V and 12 V blocks from 4.5 to 200 Ah, they pair high reliability and long service life with a compact footprint, making them a dependable reserve-power source for protecting critical systems.

Overview

DataSafe HX top terminated batteries are engineered to protect vital equipment, combining a set of design features that maximize reliability while delivering strong performance and excellent service life. Their gas-recombination VRLA chemistry keeps gas evolution to a minimum, which means they can be installed in cabinets or on stands—in offices or close to the equipment they protect—so sites can make better use of available space while cutting storage and maintenance costs. The result is a battery that delivers high performance in less space than conventional standby power batteries.

Key features and benefits

  • Positive and negative plate grids in a lead-calcium-tin alloy for long life and efficient recharge.
  • Flame-retardant case (UL94) and cover that meet UL1778.
  • Individual flame-arresting cell vents.
  • Hermetically sealed containers and covers for leak resistance across the life of the product.
  • AGM separators that fully absorb the electrolyte.
  • High-performance brass threaded receptacle, bolt, and faston terminals.
  • Increased energy density.
  • Computer-optimized electrochemistry for higher power output down to the 15-minute rate at 1.67 volts per cell.
  • 100% initial battery capacity.

Construction

  1. High-conductivity terminals — brass insert with threaded receptacle (HX80–HX800), bolt terminal (HX80–HX150), or faston tab (HX25–HX50) for maximum conductivity and easy installation.
  2. High-integrity terminal seal — compression grommet (HX205–HX800) or dual welded/epoxy seal (HX25–HX150) designed for long life.
  3. Self-regulating relief valve — a low-pressure non-return valve that prevents atmospheric oxygen from entering the cell.
  4. Rugged high-performance positive plates — grids designed to resist corrosion and prolong active life.
  5. Balanced negative plates — tuned for optimum recombination efficiency.
  6. Tough cell containers — thick-wall plastic that resists shock and vibration, with flame-retardant material as the standard offering.
  7. Separators — low-resistance microporous Absorbent Glass Mat (AGM) that holds the electrolyte.

Electrical specifications

Type Voltage (V) Nominal capacity — 8 hr rate to 1.75 Vpc (Ah) Watts/cell — 15 min rate to 1.67 Vpc Short-circuit current (A) Max discharge current — 2 min rate (A) Internal resistance (mΩ)
12HX25 12 4.5 23 300 41 16.5
12HX35 12 7 36 500 62 13.2
6HX50 6 11 53 720 93 6.1
12HX50 12 11 53 720 93 12.2
12HX80 12 16 80 1000 140 8.5
12HX100 12 21 100 1500 171 7.1
12HX135B 12 28 135 1800 238 5.6
12HX135R 12 28 135 1800 238 5.6
12HX150 12 32 150 2400 277 5.0
12HX205 12 44 205 2775 439 4.5
12HX300 12 70 284 3175 503 3.9
12HX330 12 82 336 3700 586 3.4
12HX400 12 94 381 4225 670 3.0
12HX505 12 119 506 4510 913 2.8
12HX540 12 123 540 4775 961 2.6
6HX800 6 200 780 6200 1272 1.0

Internal resistance values are for reference only and are not intended to represent an ohmic value or baseline measurement.

Physical specifications

Type Overall height (incl. terminal) Width Length Typical weight Layout Terminals
12HX25 107 mm (4.2 in) 70 mm (2.8 in) 90 mm (3.5 in) 2.0 kg (4.4 lb) 1 A/B
12HX35 100 mm (3.9 in) 65 mm (2.6 in) 151 mm (5.9 in) 2.8 kg (6.1 lb) 3 A/B
6HX50 99 mm (3.9 in) 50 mm (2.0 in) 151 mm (5.9 in) 2.1 kg (4.7 lb) 1 A/B
12HX50 99 mm (3.9 in) 99 mm (3.9 in) 152 mm (6.0 in) 4.1 kg (9.1 lb) 3 A/B
12HX80 167 mm (6.6 in) 76 mm (3.0 in) 181 mm (7.1 in) 6.4 kg (14.0 lb) 2 C/E
12HX100 175 mm (6.9 in) 125 mm (4.9 in) 166 mm (6.5 in) 10.0 kg (22.0 lb) 2 C/E
12HX135B 180 mm (7.1 in) 130 mm (5.1 in) 198 mm (7.8 in) 11.8 kg (26.0 lb) 1 F
12HX135R 169 mm (6.7 in) 130 mm (5.1 in) 196 mm (7.7 in) 11.8 kg (26.0 lb) 1 C
12HX150 170 mm (6.7 in) 165 mm (6.5 in) 197 mm (7.8 in) 14.5 kg (32.0 lb) 2 D/F
12HX205 206 mm (8.1 in) 140 mm (5.5 in) 226 mm (8.9 in) 19.5 kg (43.0 lb) 1 D
12HX300 208 mm (8.2 in) 175 mm (6.9 in) 259 mm (10.2 in) 27.2 kg (60.0 lb) 1 D
12HX330 213 mm (8.4 in) 173 mm (6.8 in) 300 mm (11.8 in) 32.2 kg (71.0 lb) 1 D
12HX400 211 mm (8.3 in) 173 mm (6.8 in) 338 mm (13.3 in) 36.3 kg (80.0 lb) 1 D
12HX505 272 mm (10.7 in) 173 mm (6.8 in) 338 mm (13.3 in) 46.7 kg (103.0 lb) 1 D
12HX540 272 mm (10.7 in) 173 mm (6.8 in) 338 mm (13.3 in) 48.1 kg (106.0 lb) 1 D
6HX800 211 mm (8.3 in) 173 mm (6.8 in) 340 mm (13.4 in) 36.3 kg (80.0 lb) 4 D

All dimensions are given at +/-0.08 in (2 mm) and include the terminal.

Constant power discharge to 1.67 Vpc at 77 °F (25 °C)

Watts per cell available over the listed standby times (minutes):

Type 5 min 10 min 15 min 20 min 30 min 45 min 60 min
12HX25 45 29 23 18 13 10 8
12HX35 71 46 36 28 20 15 12
6HX50 110 71 53 44 32 23 18
12HX50 110 71 53 44 32 23 18
12HX80 157 102 80 62 46 33 26
12HX100 197 127 100 78 57 41 33
12HX135 265 172 135 105 77 56 44
12HX150 295 191 150 117 85 62 49
12HX205 412 274 205 164 119 85 67
12HX300 558 373 284 231 174 128 102
12HX330 637 435 336 276 206 150 119
12HX400 722 498 381 313 232 170 136
12HX505 877 653 506 412 301 218 173
12HX540 930 691 540 444 326 236 186
6HX800 1320 977 780 652 494 365 291

Full constant-power discharge tables are also published at end voltages of 1.60, 1.63, 1.65, 1.70, and 1.75 Vpc. Rates are subject to change without notice.

Charging and operating parameters

  • Normal operating temperature range: −4 °F (−20 °C) to 122 °F (50 °C).
  • Float charging voltage: 2.25–2.28 volts per cell at 77 °F (25 °C).
  • Charging current: can be safely recharged at high current rates.
  • Storage time: up to 6 months at 77 °F (25 °C) before a freshening charge is required; this interval shortens at higher temperatures.
  • Orientation: designed to be installed on their base — consult your local EnerSys dealer before installing in any other orientation.

Torque specifications

  • M5 receptacle: 31 in-lbs (3.5 Nm) ±5%.
  • M6 receptacle (HX80–HX150): 44 in-lbs (5 Nm) ±5%.
  • M6 receptacle (HX205–HX800): 60 in-lbs (6.8 Nm) ±5%.
  • M5 bolt: 40 in-lbs (4.5 Nm) ±5%.
  • M6 bolt: 58 in-lbs (6.5 Nm) ±5%.

Standards and approvals

  • UL listed — File No. MH16464 (HX25–HX150) or MH12544 (HX205–HX800).
  • Manufactured to EnerSys standards in ISO 9001 registered production facilities worldwide.
  • Approved for shipping as non-hazardous, non-spillable per IATA Special Provision A67 and 49 CFR.

Cabinets and racks

DataSafe 12 V HX top terminal batteries can be housed in matching cabinets and racks. The 12 V HX battery cabinets are available in UBC at or below-grade Rated Zone 4 (Zone 4 data sheet US-HXCAB-RS; Zone 0 is not applicable). The 12 V HX battery racks are available in UBC Zone 0 as well as at or below-grade Rated Zone 4, with data sheets by model:

12 Volt battery Zone 0 data sheet Zone 4 data sheet
12HX205 US-UAAx-RK US-UJAx-RK
12HX300 US-UABx-RK US-UJBx-RK
12HX330 US-UACx-RK US-UJCx-RK
12HX400 US-UADx-RK US-UJDx-RK
12HX505 / 12HX540 US-UAEx-RK US-UJEx-RK
6HX800 US-UAFx-RK US-UJFx-RK

Cabinet accessories and inter-unit/inter-tier connections are included in cabinet pricing, sized at the 15-minute discharge rate to 1.67 V/cell end voltage. Rack accessories vary by site application and are quoted and sold separately once the system is sized.